CDV32 condensate drain valve

CDV32 condensate discharge valves automatically discharge air and condensate from steam systems during start-up. A compression spring keeps the valve open when the system is not pressurized. As soon as

the operating pressure reaches the closing pressure to which the CDV is set, the valve closes. If the operating pressure drops below the set closing pressure, the spring force will cause the CDV32 to open once again.

  • Manual relief lever to operate the valve under operating pressure under pressure for dirt removal.
  • Prevents vacuum and ice formation.
  • Built-in filter, easy to clean.

Saturated steam.

CDV32 - carbon steel.

1/2" to 3/4"; DN 15 to DN 20.

Female thread ISO 7 Rp or NPT.

Flanges EN 1092-1 PN 40.

Flanges ASME B16.5 Class 150 or 300.

Socket weld (SW) ASME B16.11.

Butt weld (BW) ASME B16.25 on request.

Vertical installation recommended.

When installed in horizontal lines, an outlet connection pipe should be installed.

When installed in horizontal lines, a downward pointing outlet connection pipe must be installed.

See IMI - Installation and Maintenance Instructions.