Noise diffusers DF15

The ADCA DF series are compact noise diffusers designed to disperse the high velocity discharge from steam or air traps, dampening noise and reducing erosion. These devices are typically installed downstream of intermittent steam traps, such as thermodynamic or inverted bucket traps, which are often associated with high velocity discharges. Noise reductions in excess of 80% can be expected when measured at a distance of 1 meter from the source.

  • Simple and compact design
  • 80% noise reduction, measured at 1 meter from the application.
  • Corrosion resistant.
  • No moving parts.

Steam or compressed air.

DF15 - outlet with threaded connection, suitable when discharging to condensate return lines.

DF16 - outlet without threaded connection, suitable for direct discharge to atmosphere.

1/2", 3/4" and 1".

ISO 7 Rp female thread.

Recommended installation position is vertical with outlet connection facing downward to the floor or other safe location. Clean before installing the diffuser.

On compressed air systems, make sure the system is oil free.

See IMI - Installation and Maintenance Instructions.